160 W, DoE Level VI & CoC Tier 2 Efficiency, Two Prong (C8) Inlet, Desktop Adapter, Ac-Dc Power Supply

GTM961600PWWWVV.V-T2 Image
Model ImageGTM961600PWWWVV.V-T2, Medical/ICT/ITE/Household use Power Supply,  60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka \
Information
Model NumberGTM961600PWWWVV.V-T2
DescriptionGTM961600PWWWVV.V-T2, Medical/ICT/ITE/Household use Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8"), Output Rating: 160 Watts, Power rating with convection cooling (W) , 12-36V in 0.1V increments, Approvals: cETLus; CB 60601-1-11; CB 60601-1; S-Mark IEC/EN 60601-1; cETLus; CB 60950; VCCI; WEEE; China RoHS; RoHS; PSE; CE; Level VI; EAC; Double Insulation; CB 60335; cETLus 60601-1 3rd; UKCA; Conforms to 62368-1; CCC; CB 62368; S-Mark 60950; ETL 62368; Morocco;RCM; IRAM; FCC; GTM961600PWWWVV.V-T2, Medical/ICT/ITE/Household use Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8"), Output Rating: 160 Watts, Power rating with convection cooling (W) , 12-36V in 0.1V increments, Approvals: cETLus; CB 60601-1-11; CB 60601-1; S-Mark IEC/EN 60601-1; cETLus; CB 60950; VCCI; WEEE; China RoHS; RoHS; PSE; CE; Level VI; EAC; Double Insulation; CB 60335; cETLus 60601-1 3rd; UKCA; Conforms to 62368-1; CCC; CB 62368; S-Mark 60950; ETL 62368; Morocco;RCM; IRAM; FCC;
Agency Documentshttp://www.globtek.info/certs/GTM961800P/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000Old6mEAB
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000Old6mEAB
CE EC-Declaration for Householdhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000Old6mEAB
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000Old6mEAB
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000Old6mEAB
UKCA-Declaration for Householdhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000Old6mEAB
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O0c00000Old6mEAB
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O0c00000Old6mEAB
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External / 桌面式/外置
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / 开关整流电源
CategoryMedical/ICT/ITE/Household use Power Supply / Medical/ICT/ITE/Household use Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)2.2A
Max Output Power Rating (W)160
Output Voltage Range (V)12-36
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress ProtectionIP41
Size (mm)176.5*74*40
Enclosure

User-added image
 
3D File Downloadhttps://www.globtek.com/dl/GTM961600-GTM961800-T2.igs
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM961600P12512-T2*1210.42125.04
GTM961600P15015-T2*1510150
GTM961600P15016-T2*169.375150
GTM961600P15018-T2*188.333149.99
GTM961600P16019-T2*198.42159.98
GTM961600P16024-T2*246.66159.84
GTM961600P16028-T2*285.714159.99
GTM961600P16036-T2*364.444159.98
GTM961600PWWWVV.V-T2-XXXXCUSTOMCUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
         90-264Vac range @ 100% of rated load current
         85-264 Vac range @ 90% of rated load current
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50/60Hz
03. Power Factor: 0.90 minimum @ 230Vac, 0.97 minimum @ 115Vac
04. Output Regulation: +/- 4% max measured at the output connector
05. Line Voltage Regulation: +/- 0.5% typical measured at full load
06. Green Power On Indicator LED
07. Output Ripple (Vp-p): 1% or 200 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with a low impedance 47 uF electrolytic capacitor connected at the end of the output connector at nominal line
08. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 25% to 50% step load
09. Turn-ON Delay: 1 second typical
10. Hold-Up Time: 20 mS minimum
11. Inrush Current: 30A maximum at 115Vac input and 60A maximum at 230Vac input
12. Switching Frequency: Varies from 25KHz to 125KHz
13. Efficiency: Compliant with DoE Efficiency Level VI standard and CoC Tier 2
14. No Load Standby Power: <0.15 W @ 230Vac

B) PROTECTION
01. Input Protection: Input line fusing and 300Vac rated MOV
02. Short Circuit/ Overload: Electronically Protected unit will auto recover upon removal of fault
         Output Current Limit: Current limited to less than 240W / Vnom and 18A for low voltage models
         (Vnom = nominal rated output voltage)
03. Over-Temperature: Latching Electronic  Overtemperature protection. Cycle AC OFF to reset.
04. Output Over-Voltage: 110% to 135% of nominal output voltage under full load condition, and less than 60V max. Latching protection, cycle AC OFF to reset.

C) SAFETY
01. Dielectric Withstand Voltage: 4000Vac or 5656Vdc from input to output,
On Class I models, 3000Vac or 4242Vdc from input to earth
02. Earth Leakage Current: Class I models < 300uA, N/A for Class II models
03. Touch Current: Class I models < 20uA, Class II models < 70uA
04. Output Isolation Options:
   a) C8 or C18 Inlet, Class II
   b) C6 or C14 Inlet, Class II FE, Output Isolated from Earth contact
   c) C6 or C14 Inlet,  Class I, Output negative directly attached to Earth contact
05. Earth Continuity Test: < 0.1 Ohm between Earth Pin at AC input and PCB termination point (Class I models only)
06. Means of Protection: 2 x MOPP
07. Primary to Secondary Bridging Capacitance: Two IEC60384-14 certified Y1 type capacitors in series
08. Compliant Standards: See listings at end of this drawing for specifics

D) EMC
EN 60601-1-2, 4th edition
Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4, CISPR11 and CISPR22
  Conducted Emissions: Class B, FCC Part 15, Class B
  Radiated Emissions: Class B, FCC Part 15, Class B
Line Frequency Harmonics EN61000-3-2, Class A
Voltage Fluctuations/Flicker EN61000-3-3
 
Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2
  Static Discharge Immunity EN61000-4-2, 10kV Contact Discharge, 18kV air discharge
  Radiated RF Immunity EN61000-4-3, 10V/m 80-2.7GHz, 80% 1KHz AM.
  EFT/Burst Immunity EN61000-4-4, 4kV/100kHz.
  Line Surge Immunity EN61000-4-5, 2kV differential, 4kV common-mode
  Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM
  Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m
  Voltage Dip Immunity EN61000-4-11, Criteria

E) OTHER:
01. MTBF: 1,000,000 Hours @ 40°C ambient temperature, Full Load
02. Operating Temperature:  -10°C to 40°C ambient temperature with full load
    Regarding Operating Temperature, 
    a- See below derating table for output power capability at alternate temperature
    b- Extended low end temperature range down to -40°C available as a custom option
03. Humidity: 0% to 95% relative humidity, non-condensing
04. Storage Temperature: -30°C to 80°C
05. Cooling: Convection
06. ROHS: Compliant with latest regulations, see approvals section below
07. Operational Altitude: 5000M

F) DESKTOP STYLE ENCLOSURE
01. Housing: High impact plastic, 94V0 polycarbonate, non-vented
02. Size: 176.5 x 74 x 40 +/-1.0 mm
03. Markings: Label or Laser printed
04. AC Input mechanical options: Desktop C6, C8, C14 or C18 IEC Inlet.

G) SPECIAL OPTIONS
01. Custom Cordsets, various cordage types, and connector types
02. Custom Markings
03. Short term Output Surge Power Capability, for motor applications, and short term intermittent high power need applications. 300W for 1 second is available, as a special design variant.
04. Reduced Leakage Current version, medical CF leakage current compliance
05. Tightened output voltage tolerance
06. Reduced Output Ripple Level
08. Reduced output power marking/rating
09. High Rel PCB laminate with Plated through Holes for IPC610 Class 2 Compliance
10. Special Housing Colors and Cordset Colors
11. LED Lighting Applications, Class C Line Harmonics
12. Constant Current output, for Vnom to 0.75xVnom.  Add “-CC” suffix to model number. Current level is custom selectable.
13. Back EMF applications, custom solutions. For unusual motor load aps and other high inductance reverse energy flow requirements
14. Improved Ingress Protection Rating



H) OUTPUT CONNECTORS
Several output connector options are available with various output current ratings.
GlobTek can supply 10A rated 2.1mm and 2.5mm style DC Power Jacks, to complement our
10A output rated 2.1mm and 2.5mm DC power plugs used on our output cordsets.
Please visit https://en.globtek.com/news/high-current-coaxial-barrel-plug-jacks-for-high-wattage-power-supplies for a real time product offering of mating connectors.
 
Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)465 x 415 x 225
Gross Weight (kg)16
Label Width (mm)41.0
Label Height (mm)71.0
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8")
User-added image
Mates with IEC 60320/C7 Plug

Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Please contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

Standard International IEC 320/C7 Cordsets 
Part NumberTypeStandardConnectorLength (mm)Length (feet)
2094112M703(R)Argentina (Type I)IRAM 2063IEC 320/C720007
5014112M703A(R)Australian (Type I)AS 3112IEC 320/C720007
207B4111M8703(R)Brazil (Type N)NBR14136IEC 320/C718006
4533501M8703(R)China (Type A)GB 2099.1IEC 320/C718306
2074112M703A(R)European (Type C)CEE 7/16IEC 320/C720007
2074112M703AEUSA(R)European/South Africa Combo(Type C)CEE 7/16IEC 320/C720007
2084111M8703B(R)India (Type D)IS 1293IEC 320/C718006
451J3401M8703(R)Japan (Type A)JIS 8303IEC 320/C718306
2044112M703A(R)Korea (Type C)KS C8305IEC 320/C720007
4511116F703A(R)North America (Type A)NEMA 1-15PIEC 320/C718306
2084111M8703(R)South Africa (Type M)BS 546IEC320/C718306
4033401M8703A(R)Taiwan (Type A)CNS690IEC 320/C718306
6104112M703A(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363IEC 320/C720007
451G1116F703A(R)Gulf States (Kuwait, Bahrain, Oman, Qatar, Saudi Arabia, Yemen and the United Arab Emirates (UAE)(Type A)Nema 1-15PIEC320/C718306
6303742M5703(R)Thailand (Type C)TIS 166-2549IEC320/C725008
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)

No Logo Applicable

IEC 60601-1-11:2015
No Logo ApplicableIEC 60601-1: 2005 + C1 + C2 + A1

No Logo Applicable

CB for IEC 60335-1:2010/COR1:2010/COR2:2010 /AMD1:2013/COR1:2014/AMD2:2016/COR1:2016

No Logo Applicable

CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added imageCCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008

User-added image  
CE Certification
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageConforms to ANSI/UL Std. 60950-1 2nd Edition Cert. to CAN/CSA Std.C22.2 NO.60950-1 2nd Edition
User-added image
 
cETLus-Cert-4007497 ANSI/AAMI ES60601-1:2005 with AMD C1: 2009, AMD C2: 2010 and CAN/CSA-C22.2 No. 60601-1 2008 with COR 2:2011+ANSI/AAMI HA60601-1-11 Ed:1
User-added image
 
cETLus-Cert-60950-1 4007497 Listed
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageCompliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
User-added image
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE
 
IRAM certificate DC-E-G71-007.2 to IEC 62368-1:2014
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
User-added imageRCM certificate SAA-200887-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
EN 60601-1:2006 + A1:2013 + A12:2014 EN 60601-1-11:2015
User-added image
 
S-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
User-added imageUKCA Certification
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request

什么是IEC 60601-1医疗级额定电源交流适配器?

IEC 60601-1-2医疗级额定电源交流适配器将来自墙壁的输入线路电压转换为较低的电压,通常为直流,该电压用于操作和最终使用医疗设备。 IEC 60601-1-2医疗级电源交流适配器通常装在塑料外壳中,并提供2脚和3脚输入选项。另外开放式电源医疗设备内部.这些交流转直流转换器是根据国际医学标准设计的,并确保它们符合某些方面的要求,不同于通用信息和通信技术设备的电源。
 

为什么医疗级IEC 60601-1电源通过了IEC 60601-13版认证,而最新标准IEC 60601-14版?

IEC 60601-1在安全和EMI / EMC规范中有区分IEC 60601-1安全部分的最新版本是第三版,而EMI / EMC的最新版本是60601-1-2,第四版。

 

第四版60601-1-2什么时候生效?

第四版60601-1-220181231日起生效。

 

IEC 60950-1IEC 60601-1医疗级额定电源有什么区别?

IEC 60950-1IEC 60601-1-2电源都是起到交流电转直流电的作用,可以是内或外根据应用终端的不同规格要求而设计。 尽管例如输入和输出电压以及结构等类似,但也存在许多差异。 例如一些重要区别在于,医用IEC 60601医用级交流转直流适配器能够承受较高电压,并且必须具有较低的漏电流。 根据终端应用的不同,还有许多其他差异和考虑因素。

什么是MOOP (MEANS OF OPERATOR PROTECTION )对操作者提供足够防护 和MOPP (MEANS OF PATIENT PROTECTION) 对病患提供足够防护
医疗设备必须包含一种或多种保护手段(MOP),以使患者和操作员免受电击危险。 保护手段(MOP)可以是安全绝缘,保护性接地,规定的爬电距离或气隙或其他保护性阻抗。 这些可以各种组合使用。 IEC 60601-13版区分了对患者的风险和对操作人员的风险。 因此,MOP可以分类为患者保护方式(MOPP)或操作员保护方式(MOOP)。 MOOPMOPP之间的主要区别是允许的爬电距离。 使用基本绝缘可以满足这两个要求。 为了获得2倍的MOPP认证,隔离测试在4000 Vac时特别要求,8mm的爬电距离是MOPP所要求的两倍。

什么是主体触体绝缘型和心脏触体绝缘型符合IEC 60601-1-2医疗级额定电源交流适配器,有什么区别?

医用级电源和交流转直流适配器分为三种应用部件类型:主体类型(B),主体触体绝缘型(BF)和心脏触体绝缘型(CF)。这些应用的零件需要特定的属性,例如隔离电压,爬电距离和漏电流。绝缘是指未接地的II类电源,该电源未关联到另一个输出且已完全隔离。 B型是指在患者附近工作的设备,如IEC 60601-1中所述,围绕患者的椅子或床六英尺,并且不通过电子方式接触患者并且接地。这些设备包括手术室照明设备,医院推车和床,药物和补给品的自动分配器以及X射线机之类的诊断设备。 BF型设备向患者或从患者发送电能信号,例如电外科设备,内窥镜和生命体征电子监护仪(例如温度计)。 CF型设备与BF类似,不同之处在于它们为连接到心脏的设备(例如除纤颤器,外部起搏器或心内心电图电极)供电,并且CF型需要比BF型更高的电击防护等级。

POE电源是否需要VI级效率?
根据美国能源部的规定,如果EPS使用任何类型的电气连接,电缆,软线或其他电线(包括可移动的和硬的)连接到最终用途应用,则可以被视为AEPS。 有线连接。 以太网电缆将满足这些标准,因此通过以太网电缆连接到最终用途产品的EPS仍将被视为AEPS,并且如果满足其他5条标准,则将遵守适用的节能标准。 AEPS。 通常,所有以太网供电电源适配器都符合所有标准,并且必须达到VI级效率
 

什么是符合IEC 62368-1:2018标准电源?
IEC 62368-12018适用于额定电压不超过600 V的音频,视频,信息和通信技术以及商用和办公领域中的电气和电子设备安全。这是产品安全标准 对能源进行分类,规定针对这些能源的防护措施,并就这些防护措施的应用和要求提供指导。 规定的防护措施旨在减少痛苦,受伤的可能性,并在发生火灾时减少财产损失。 符合IEC 62368-1交流直流转换器或电源是经过测试并证明符合所述标准的电源。

IEC 62368-1电源是否替代了IEC60950-1电源?20201220日,已应用于信息技术设备和音频视频设备的安全标准IEC 60065IEC 60950-1过渡为IEC 62368-1。 在北美,ETLUL 60950-1认证将继续有效,并且可以继续使用直至另行通知。

IEC 62368-1IEC 60950-1电源之间有什么区别?

尽管标准结构和内容总体上有很大不同,但以前符合IEC 60950-1的大多数产品经过很小的修改甚至不用修改都可以符合最新标准IEC 62368-1

IEC60950-1电源是否仍然可用?
GlobTek将继续无限期地制造和供应
IEC 60950-1电源,直至另行通知。

什么是六级能效?

一到六是国际能效标记协议,允许制造商指定产品的效率性能。 此性能基于对在不同负载水平下测试的外部电源或交流转直流适配器的工作能效和空载功耗的测量。 空载功耗是指即使应用程序关闭或断开连接,外部电源也要消耗的电量。

能效是否必须?
些国家和地区,某些产品或某些应用要求达到能效

什么是生态设计指令2009/125 / EC

生态设计指令在欧洲将交流转直流适配器和外部电源的能效和节能最新要求纳入法律。

交流直流适配器如何工作?

交流直流适配器或外置电源由与交流插头相似的外壳中封闭的电源组成,因此,术语为插头类型,插墙式,插入式或插头式电源适配器。 将电源插入电源插座,然后将交流电压通过交流到直流适配器电源转换为直流电压,该直流电压通过输出电缆连接输入到设备中。不同负载水平下测试的电源的工作能效和空载功耗 空载功耗是指即使应用设备关闭或断开连接,外置电源也要消耗的电量。

问询
Call
Email
💬
Text
💁
Chat
?
询价
我们可以帮助您?
我们可以帮助您?