GTM86101-WWVV-W2A Wall Plug-in ICT / ITE / Medical Power Supply Datasheet
GTM86101-WWVV-W2A Image | |||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model Image | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||
Information | |||||||||||||||||||||||||||||||||||||||||||||||||
Model Number | GTM86101-WWVV-W2A | ||||||||||||||||||||||||||||||||||||||||||||||||
Description | GTM86101-WWVV-W2A, ICT / ITE / Medical Power Supply, Wall Plug-in, AC Adaptor Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, Australian AS 3112 configuration: SAA 2 pins Class II, Output Rating: 10 Watts, Power rating with convection cooling (W) , 5.95-24V in 0.1V increments, Approvals: CB 60601-1-11; IP22; CE; China RoHS; Double Insulation; EAC; Level VI; RoHS; Ukraine; VCCI; WEEE; CB 60601-1; GTM86101-WWVV-W2A, ICT / ITE / Medical Power Supply, Wall Plug-in, AC Adaptor Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, Australian AS 3112 configuration: SAA 2 pins Class II, Output Rating: 10 Watts, Power rating with convection cooling (W) , 5.95-24V in 0.1V increments, Approvals: CB 60601-1-11; IP22; CE; China RoHS; Double Insulation; EAC; Level VI; RoHS; Ukraine; VCCI; WEEE; CB 60601-1; | ||||||||||||||||||||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GTM86101/ | ||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | https://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000LvrtQEAR | ||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000LvrtQEAR | ||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | https://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000LvrtQEAR | ||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000LvrtQEAR | ||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O3a00000LvrtQEAR | ||||||||||||||||||||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0O3a00000LvrtQEAR | ||||||||||||||||||||||||||||||||||||||||||||||||
Prop 65 Statement | https://en.globtek.com/prop-65-statement.pdf | ||||||||||||||||||||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/pdf/iso_certificates/REACH.pdf | ||||||||||||||||||||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/pdf/conflict-minerals.pdf | ||||||||||||||||||||||||||||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||||||||||||||||||||||||||||
Type | Wall Plug-in / 插墙式 | ||||||||||||||||||||||||||||||||||||||||||||||||
Technology | AC Adaptor Power Supply AC Adaptor / 交流转交流适配器 | ||||||||||||||||||||||||||||||||||||||||||||||||
Category | ICT / ITE / Medical Power Supply / ICT / ITE / Medical Power Supply | ||||||||||||||||||||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60Hz | ||||||||||||||||||||||||||||||||||||||||||||||||
Max Input Current (A) | 0.3A | ||||||||||||||||||||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 10 | ||||||||||||||||||||||||||||||||||||||||||||||||
Output Voltage Range (V) | 5.95-24 | ||||||||||||||||||||||||||||||||||||||||||||||||
Efficiency | USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 | ||||||||||||||||||||||||||||||||||||||||||||||||
Ingress Protection | IP22 | ||||||||||||||||||||||||||||||||||||||||||||||||
Size (mm) | 69*42.4*49.5 | ||||||||||||||||||||||||||||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||||||||||||||||||||||||||||
3D File Download | https://www.globtek.com/dl/GTM86101-WWVV-W2A.stp | ||||||||||||||||||||||||||||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||||||||||||||||||||||||||||||||||||||
Specifications | |||||||||||||||||||||||||||||||||||||||||||||||||
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50/60Hz 03. Output Regulation: +/- 5% 04. Line Voltage Regulation: +/- 1% 05. Output Ripple (Vp-p): 1% or 100 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with a low impedance 47 uf electrolytic capacitor connected at the end of the output connector 06. Hold-up Time: 5 mS minimum 07. Inrush Current: 30A maximum @ 230Vac input 08. Energy Efficiency: Complies to Efficiency Level VI and ErP European Commission's Ecodesign Directive (2005/32/EC) / CoC Tier 2 Compliant B) PROTECTION 01. Over-current protection: 110%-140% maximum with auto-recovery function 02. Output Over-Voltage: 110% to 130% of nominal output voltage 03. Short-circuit protection: The adapter shall not be damaged by short the DC output to Ground. C) SAFETY 01. Dielectric Withstand Voltage: Primary To Secondary: 4000VAC or 5656VDC for 3 seconds 02. Leakage Current: 50uA maximum, at nominal 240Vac input voltage 03. ESD Immunity per EN61000-4-2, ±8 kV contact, ±15 kV air, Perf Criteria A Standard. D) EMC 01. Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4 Conducted Emissions: Class B, FCC Part 15, Class B Radiated Emissions: Class B, FCC Part 15, Class B 02. Line Frequency Harmonics EN61000-3-2, Class A 03. Voltage Fluctuations/Flicker EN61000-3-3 04. Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2 Static Discharge Immunity EN61000-4-2, 8kV Contact Discharge, 15kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m 80-2700MHz, 80% 1KHz AM. EFT/Burst Immunity EN61000-4-4, 2kV/100kHz. Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM Power Frequency Magnetic Field Immunity EN61000-4-8, NA Voltage Dip Immunity EN61000-4-11, Criteria E) OTHER: 01. MTBF: 300,000 Hours @ 25°C ambient temperature 02. Operating Temperature: 0°C to 50°C ambient temperature 03. Operating Humidity: 20 ~ 85 % RH. non-condensing 05. Storage Temperature: -20°C to 60°C 06. Storage Humidity:5 ~ 95 % RH. non-condensing 07. Cooling: Natural convection cooling 08. RoHS 2: Complies with EU 2011/65/EU China SJ/T 11364-2014 F) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Markings: Label and/or Pad Printed and/or Molded in the case F) OPTIONS: 01. Green Power On Indicator LED 02. NEMA 1-15P or European Schuko 7-16 AC Plug Configuration 03. Increased DC Output Voltage (up to 5.4V) to allow for long output cables 04. Special International Safety Approvals 05. Housing Color, special markings | |||||||||||||||||||||||||||||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||||||||||||||||||||||||||||
Qty (ea.)/Carton | 120 | ||||||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 90*54*76 | ||||||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||||||||||||||||||||||||||||||||||
Master Carton Size (mm) | 470 x 345 x 340 | ||||||||||||||||||||||||||||||||||||||||||||||||
Gross Weight (kg) | 15.6 | ||||||||||||||||||||||||||||||||||||||||||||||||
Label Width (mm) | 39.7 | ||||||||||||||||||||||||||||||||||||||||||||||||
Label Height (mm) | 16.2 | ||||||||||||||||||||||||||||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||||||||||||||||||||||||||||
Description | Australian AS 3112 configuration: SAA 2 pins Class II Used in Australia, New Zealand, Fiji, Papua New Guinea and Tokelau, has two flat pins forming an inverted V-shape. These flat blades measure 6.3 by 1.5 mm with the Active and Neutral pins of 17 mm in length set 30° to the vertical on a nominal pitch of 13.7 mm. A standard power outlet in Australia provides a nominal voltage of 230 volts at a maximum of 10 amps and always includes an earth connection. As in the UK, its outlets are individually switched for extra safety. Argentina uses a similar plug, with pins 1 mm longer.
| ||||||||||||||||||||||||||||||||||||||||||||||||
Output Configuration | |||||||||||||||||||||||||||||||||||||||||||||||||
Common output connector options: Click to add to your request.
For a comprehensive list of options, click here Contact GlobTek for your specific requirements or custom solutions. | |||||||||||||||||||||||||||||||||||||||||||||||||
Approvals | |||||||||||||||||||||||||||||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | |||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||
Popular Products (Stock items) | |||||||||||||||||||||||||||||||||||||||||||||||||
|
什么是六级能效?
一到六是国际能效标记协议,允许制造商指定产品的效率性能。 此性能基于对在不同负载水平下测试的外部电源或交流转直流适配器的工作能效和空载功耗的测量。 空载功耗是指即使应用程序关闭或断开连接,外部电源也要消耗的电量。
六级能效是否必须?
在一些国家和地区,某些产品或某些应用要求达到六级能效
什么是生态设计指令2009/125 / EC?
生态设计指令在欧洲将交流转直流适配器和外部电源的能效和节能最新要求纳入法律。
什么是插墙式交流直流适配器?
插墙式交流直流适配器也称为交流适配器或交直流转换器,是一种外部电源。 一些电器需要电源来驱动,但是缺少内部组件而不能从市电中获得所需的电压和电源,此时便需要使用交流适配器将交流电流转换为直流电压
交流直流适配器如何工作?交流直流适配器或外置电源由与交流插头相似的外壳中封闭的电源组成,因此,术语为插头类型,插墙式,插入式或插头式电源适配器。 将电源插入电源插座,然后将交流电压通过交流到直流适配器电源转换为直流电压,该直流电压通过输出电缆连接输入到设备中。