GlobTek's GTM961200 series of external tabletop/desktop power supplies offer up to 120W of power while offering compliance to the latest ITE, Medical, Household, and Efficiency requirements.

GTM961200P120VV.V-T3 Image
Model ImageGTM961200P120VV.V-T3, ICT / ITE / Medical Power Supply,  60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C14 AC Inlet Connector,  Class I,  Earth Ground, Output Rating: 120 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: CB 61347; RCM; CCC; EAC; cETLus 60950-1; cETLus 60601-1-11; S-Mark 62368; IRAM; Malaysia; NOM (24V only); UKCA; Taiwan BSMI (12,15,18,19,24,48,54V only); Conforms to 62368-1; NrCAN (12V only); Morocco; Korea (24,25,26 and 27V Only); Korea (12V and 13V Only); ETL (Brazil); NOM (12V only); South Africa (pending); India BIS (12,15,18,19,24,28,30,48 and 54V); Israel (24V only); Singapore (24V); ETL; S-Mark 60950; CB 60950; CB 60335; CB 62368; ETL; CB 60335; VCCI; CB 60601-1; S-Mark; WEEE; Ukraine; RoHS; ETL 62368; Level VI; China RoHS; CE; Class I; PSE; PSE; PSE; GTM961200P120VV.V-T3, ICT / ITE / Medical Power Supply,  60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C14 AC Inlet Connector,  Class I,  Earth Ground, Output Rating: 120 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: CB 61347; RCM; CCC; EAC; cETLus 60950-1; cETLus 60601-1-11; S-Mark 62368; IRAM; Malaysia; NOM (24V only); UKCA; Taiwan BSMI (12,15,18,19,24,48,54V only); Conforms to 62368-1; NrCAN (12V only); Morocco; Korea (24,25,26 and 27V Only); Korea (12V and 13V Only); ETL (Brazil); NOM (12V only); South Africa (pending); India BIS (12,15,18,19,24,28,30,48 and 54V); Israel (24V only); Singapore (24V); ETL; S-Mark 60950; CB 60950; CB 60335; CB 62368; ETL; CB 60335; VCCI; CB 60601-1; S-Mark; WEEE; Ukraine; RoHS; ETL 62368; Level VI; China RoHS; CE; Class I; PSE; PSE; PSE;
Information
Model NumberGTM961200P120VV.V-T3
DescriptionGTM961200P120VV.V-T3, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C14 AC Inlet Connector, Class I, Earth Ground, Output Rating: 120 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: CB 61347; RCM; CCC; EAC; cETLus 60950-1; cETLus 60601-1-11; S-Mark 62368; IRAM; Malaysia; NOM (24V only); UKCA; Taiwan BSMI (12,15,18,19,24,48,54V only); Conforms to 62368-1; NrCAN (12V only); Morocco; Korea (24,25,26 and 27V Only); Korea (12V and 13V Only); ETL (Brazil); NOM (12V only); South Africa (pending); India BIS (12,15,18,19,24,28,30,48 and 54V); Israel (24V only); Singapore (24V); ETL; S-Mark 60950; CB 60950; CB 60335; CB 62368; ETL; CB 60335; VCCI; CB 60601-1; S-Mark; WEEE; Ukraine; RoHS; ETL 62368; Level VI; China RoHS; CE; Class I; PSE; PSE; PSE; GTM961200P120VV.V-T3, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C14 AC Inlet Connector, Class I, Earth Ground, Output Rating: 120 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: CB 61347; RCM; CCC; EAC; cETLus 60950-1; cETLus 60601-1-11; S-Mark 62368; IRAM; Malaysia; NOM (24V only); UKCA; Taiwan BSMI (12,15,18,19,24,48,54V only); Conforms to 62368-1; NrCAN (12V only); Morocco; Korea (24,25,26 and 27V Only); Korea (12V and 13V Only); ETL (Brazil); NOM (12V only); South Africa (pending); India BIS (12,15,18,19,24,28,30,48 and 54V); Israel (24V only); Singapore (24V); ETL; S-Mark 60950; CB 60950; CB 60335; CB 62368; ETL; CB 60335; VCCI; CB 60601-1; S-Mark; WEEE; Ukraine; RoHS; ETL 62368; Level VI; China RoHS; CE; Class I; PSE; PSE; PSE;
Agency Documentshttp://www.globtek.info/certs/GTM961200P/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MjJKDEA3
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MjJKDEA3
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MjJKDEA3
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MjJKDEA3
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000MjJKDEA3
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000MjJKDEA3
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External / 桌面式/外置
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / 开关整流电源
CategoryICT / ITE / Medical Power Supply / ICT / ITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5 A
Max Output Power Rating (W)120
Output Voltage Range (V)12-54
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress ProtectionIP41
Size (mm)149.30*62.80*34.00
EnclosureUser-added image
Alternative housing with input cord clamp to prevent accidental removal of the power cord. Product PN# ends with suffix "CL"
User-added image
3D File Downloadhttps://www.globtek.com/dl/GTM96900-GTM961200-T3.igs
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM961200P10812-T3*129108
GTM961200P11012-T3*129.2110.4
GTM961200P12015-T3*158120
GTM961200P12019-T3*196.316120
GTM961200P10019-T3*195.263100
GTM961200P12024-T3*245120
GTM961200P12028-T3*284.28119.84
GTM961200P12030-T3*304120
GTM961200P12036-T3*363.33119.88
GTM961200P12038-T3*383.15119.7
GTM961200P12048-T3*482.5120
GTM961200P12054-T3*542.22119.88
GTM961200P120VV.V-T3-XXXXCUSTOMCUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       90% rated load current for 85-264VAC
     100% rated load current for 90-370VDC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
Power Factor:0.90 min. @ 230VAC, 0.97 min. @ 115VAC
No Load Input Power:< 150mW @ 115/230VAC
Inrush Current:< 65A @ 115VAC, < 130A @ 230VAC (cold start)
Efficiency:DoE Level VI and EU CoC Tier 2 compliant

Output

Turn-on Delay:1 second typ.
Output Regulation:± 4% (measured at output connector)
Line Regulation:± 0.5% typ. (measured at output connector, full load)
Ripple:1% or 200mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Startup Overshoot:5% max.
Transient Response:5% max. deviation, 1ms typ. recovery time (with 25% to 50% load step)
Hold-up Time:20ms min.
Power Indicator:Green LED
Switching Frequency:Variable, 25KHz - 125KHz, depending on load

Protections

Input Protection:300VAC MOV transient suppressor, input line fusing
Over-Current ProtectionCurrent limited to less than < 170W / Vout(nom.) and  < 13A, auto-restart
Short-Circuit Protection:Auto-restart
Over-Voltage Protection:110 - 135% (60V max for models rated 45 - 54V), full load condition, latched off, cycle AC to reset
Over-Temperature ProtectionInternal ambient NTC temperature sensor, latched off, cycle AC to reset

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-10°C to 40°C (full load)
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m
Cooling:Convection
RoHS:Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:Regarding operating temperature
a. See below de-rating table for output power capability at alternate temperature
b. Extended low-end temperature range available as a custom option
 

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:Class I: 20µA max.
Class II: 70µA max.
Earth Leakage CurrentClass I: 300µA max.
Class II: N/A
Means of Protection:2 x MOPP
Output Isolation Options:Class I: C6 or C14 inlet (output negative tied to Earth contact)
Class II: C8 or C18 inlet
Class II FE: C6 or C14 inlet (output isolated from Earth contact)
Review isolation options by reading our white paper PSU Isolation and Identity.
Primary-to-Secondary Bridging Capacitors:Two IEC60384-14 Class Y1 capacitors
Earth Continuity Test:< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:See listing at end of this datasheet for specific standards

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 18KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-1000MHz,  3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
Size:149.4 * 62.6 * 33.5mm, ± 1.0mm
AC Input Mechanical Options:C6, C8, C14, or C18 IEC inlet
Markings:Label and/or pad printed and/or laser-etched into case

Special Options

  1. Reduced leakage current to meet IEC60601-1 Type-CF limits
  2. Improved EN61000-4-5 line surge immunity (3KV differential, 5KV common-mode)
  3. Reduced harmonic current levels for LED lighting (EN61000-3-2 Class C) for 85 - 120W load
  4. Short term output surge capability for motors or other high peak current loads
  5. Ruggedized construction with improved shock and vibration resistance
  6. Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3
  7. Custom cordsets, special cordage and connector types
  8. Custom housing markings
  9. Custom housing/cordage colors
  10. Tightened output voltage tolerance
  11. Reduced output ripple level
  12. Reduced output power rating
  13. Low temperature option, down to -40°C
  14. Epoxy potted version "P2" or "P3" suffix, with flying wires or custom cables
  15.  "Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
  16. Improved ingress protection (IP) rating

Output Connectors

 

Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)427 x 405 x 158
Gross Weight (kg)11.3
Label Width (mm)50
Label Height (mm)110
Input Configuration
DescriptionIEC 60320/C14 AC Inlet Connector, Class I, Earth GroundUser-added image
Mates with IEC 60320/C13 Plug

Optional Locking IEC60320 Receptable and cord option available on some models by request.:
User-added image

Standard International IEC 320/C13 Cordsets

Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

 

Stock Power Supply Cords

Part Number/ LinkCountryPlugTerminationLength (mm)(Ft)
3021457F701(R)N. American (Type B)NEMA 5-15PIEC 320/C1321507
1191068F0701(R)N. American (Type B)NEMA 5-15P HospitalIEC 320/C1324598
2194272M5701-T(R)Argentina (Type I)IRAM 2073IEC 320/C1325008
5502022M5701A(R)Australian (Type I)AS3112 / 3 PRONGIEC 320/C1325008
204B4272M5701(R)Brazil (Type N)BRAZILIEC 320/C1325008
6023602M5701(R)China (Type I)CCC GR2099IEC 320/C1325008
G8014272M5701(R)Danish (Type K)AFSNIT SECTION 107-2-D1IEC 320/C1325008
23144272M5701-T(R)Europe (Type E)CEE 7/7IEC 320/C1325008
23134272M5701EUKR(R)Europe/Korea Combo (Type E)CEE 7/7 / KSC8305IEC 320/C1325008
205IN4272M5701(R)India (Type D)India IS 1293 (also known as IA16A3 or BS546)IEC 320/C1325008
208IN4272M5701(R)India (Type M)India IS 1293 (also known as IA16A3 or BS546)IEC320/C1325008
377C4272M5701(R)Israel (Type H)ISL 377CIEC 320/C1325008
23024272M5701(R)Italy (Type L)CEI 23-16/VIIIEC 320/C1325008
3003339F701(R)
[3x1.25mm2]

3003068F2701-HK(R)
[3 x 2.0mm2]
Japan (Type B)JIS 8303 / 3 PINSIEC 320/C1325008
302J115J6F0701J(R)North America / Japan (Type B – 12A)NEMA 5-15P (cULus approved), Japan JIS C 8303 (PSE Approved)IEC 320/C1318306
302J104J6F0701J(R)North America / Japan (Type B – 15A)NEMA 5-15P (cULus approved), Japan JIS C 8303 (PSE Approved)IEC 320/C1318306
302JT104J9F0701JT(R)North America / Japan / Taiwan (Type B – 15A)NEMA 5-15P (cULus approved), Japan JIS C 8303 (PSE Approved), Taiwan CNS 6797 (BSMI Approved)IEC 320/C1328009
2313K3432M5701(R)Korea (Type F)KS C 8305IEC 320/C1325008
5804272M5701(R)Russia (Type F)GOST 7396IEC 320/C1325008
2084272M5701(R)South Africa (Type M)South Africa SABS164-1 (16A type)IEC 320/C1325008
23214272M5701(R)Switzerland (Type J)SEV 1011IEC 320/C1325008
3003322M5701(R)Taiwan (Type B)BSMIIEC 320/C1325008
6363762M5701(R)Thailand (Type O)TIS 166-2549IEC 320/C1325008
PZ0800100-2M5BK13H(RUK, Hong Kong,Singapore, Gulf States (Type G)BS 1363AIEC 320/C1325008
7055002M5701A(R)InternationalIEC 320 C14-C13IEC 320/C1325008
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
User-added imageTaiwan BSMI GTM961200P-T3(A) R32282 GTM961200P-T3(A); http://www.bsmi.gov.tw/wSite/ct?xItem=4072&ctNode=816&mp=2

No Logo Applicable

CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

No Logo Applicable

CB for IEC 60601-1:2006/A1:2013+A12:2014 IEC 60601-1-11:2015

No Logo Applicable

CB for IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013

No Logo Applicable

IEC 60335-1.2010+A1

No Logo Applicable

CB for IEC61347-1:2015 + A1:2017 IEC61347-2-13:2014, A1:2016

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added imageCCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008
User-added image  Test standard: EN 55032: 2012+AC: 2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024:2010 EN 60601-1-2:2015
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11
Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to UL STD. 60950-1 
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageMedical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance (R2012) [AAMI ES60601-1:2005 +C1;A2] [CSA C22.2#60601-1:2014 Ed.3] [AAMI HA60601-1-11:2015 Ed.2]
User-added imageInformation Technology Equipment Safety Part 1: General Requirements >Valid without technical revision: 01Jan2022< [UL 60950-1:2007 Ed.2 +R:14Oct2014]


 
ETL (Brazil) to IEC 62368-1;2014 DOC cert
User-added imageBureau Of Indian Standards for GTM961200P-T3 (12,15,18,19,24,28,30,48 and 54V)
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
User-added image
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE
 
IRAM certificate DC-E-G71-005.1 to IEC 62368-1:2014
User-added imageElectric strength Of Israel Standard SI 60950 Part 1 ? Safety of information technology equipment: General requirements, Feb. 2012. (GTM961200P12024-T3 Only)
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageKorea KET KC Mark GTM961200P11012-T3(A) HU10499-21046A (12V & 13V Only)
User-added imageKorea KET KC Mark GTM961200P12024-T3 HU10499-21048A (24,25,26 and 27V Only)
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
No Logo Malaysia ST Release Letter GTM961200P T2 T3(A) IEC62368-1(Ed.2): No logo
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added imageNOM MEXICO -ANCE FOR GTM961200P11012-T3; GTM961200P10812-T3 (12V)
User-added imageNOM MEXICO -ANCE FOR GTM961200P12024-T3 (24V)
User-added imageNatural Resources Canada (NRCan): CSA Standard C381.1-08, QSP NRCAN EEV1191; for model: GTM961200P10812-T3, -T3A, -T3TAB, -T2, -T2A, http://shop.csa.ca/en/canada/energy-efficiency/cancsa-c3811-08/invt/27024802008
User-added imageRCM certificate SAA-170646-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
S-Mark Certificate EN 60601-1:2006 + A1:2013 + A12:2014 EN 60601-1-11:2015 (http://www.intertek.com/marks/s/)
User-added image
 
S-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
User-added image
 
S-Mark Certificate EN 62368-1:2014 + A11 (http://www.intertek.com/marks/s/)
User-added image
Serial Number Information
User-added imageSingapore to IEC 62368 (for 24V only)
 No LogoSOUTH AFRICAN EMI/EMC SABS (pending)
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample RequestDistributor Stock (Click to order)
27129712.09.04 Pin Locking Kycon or Equal
195181220.06.04 Pin Locking Kycon or Equal
35879024.05.0Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
35878924.05.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
TR9CI5000YL4CIMR6B24.05.04 Pin Locking Kycon or Equal26
22786148.02.5Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
TR9CX2222T00-IM(R6B)54.02.22T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)3

什么是IEC 60601-1医疗级额定电源交流适配器?

IEC 60601-1-2医疗级额定电源交流适配器将来自墙壁的输入线路电压转换为较低的电压,通常为直流,该电压用于操作和最终使用医疗设备。 IEC 60601-1-2医疗级电源交流适配器通常装在塑料外壳中,并提供2脚和3脚输入选项。另外开放式电源医疗设备内部.这些交流转直流转换器是根据国际医学标准设计的,并确保它们符合某些方面的要求,不同于通用信息和通信技术设备的电源。
 

为什么医疗级IEC 60601-1电源通过了IEC 60601-13版认证,而最新标准IEC 60601-14版?

IEC 60601-1在安全和EMI / EMC规范中有区分IEC 60601-1安全部分的最新版本是第三版,而EMI / EMC的最新版本是60601-1-2,第四版。

 

第四版60601-1-2什么时候生效?

第四版60601-1-220181231日起生效。

 

IEC 60950-1IEC 60601-1医疗级额定电源有什么区别?

IEC 60950-1IEC 60601-1-2电源都是起到交流电转直流电的作用,可以是内或外根据应用终端的不同规格要求而设计。 尽管例如输入和输出电压以及结构等类似,但也存在许多差异。 例如一些重要区别在于,医用IEC 60601医用级交流转直流适配器能够承受较高电压,并且必须具有较低的漏电流。 根据终端应用的不同,还有许多其他差异和考虑因素。

什么是MOOP (MEANS OF OPERATOR PROTECTION )对操作者提供足够防护 和MOPP (MEANS OF PATIENT PROTECTION) 对病患提供足够防护
医疗设备必须包含一种或多种保护手段(MOP),以使患者和操作员免受电击危险。 保护手段(MOP)可以是安全绝缘,保护性接地,规定的爬电距离或气隙或其他保护性阻抗。 这些可以各种组合使用。 IEC 60601-13版区分了对患者的风险和对操作人员的风险。 因此,MOP可以分类为患者保护方式(MOPP)或操作员保护方式(MOOP)。 MOOPMOPP之间的主要区别是允许的爬电距离。 使用基本绝缘可以满足这两个要求。 为了获得2倍的MOPP认证,隔离测试在4000 Vac时特别要求,8mm的爬电距离是MOPP所要求的两倍。

什么是主体触体绝缘型和心脏触体绝缘型符合IEC 60601-1-2医疗级额定电源交流适配器,有什么区别?

医用级电源和交流转直流适配器分为三种应用部件类型:主体类型(B),主体触体绝缘型(BF)和心脏触体绝缘型(CF)。这些应用的零件需要特定的属性,例如隔离电压,爬电距离和漏电流。绝缘是指未接地的II类电源,该电源未关联到另一个输出且已完全隔离。 B型是指在患者附近工作的设备,如IEC 60601-1中所述,围绕患者的椅子或床六英尺,并且不通过电子方式接触患者并且接地。这些设备包括手术室照明设备,医院推车和床,药物和补给品的自动分配器以及X射线机之类的诊断设备。 BF型设备向患者或从患者发送电能信号,例如电外科设备,内窥镜和生命体征电子监护仪(例如温度计)。 CF型设备与BF类似,不同之处在于它们为连接到心脏的设备(例如除纤颤器,外部起搏器或心内心电图电极)供电,并且CF型需要比BF型更高的电击防护等级。

POE电源是否需要VI级效率?
根据美国能源部的规定,如果EPS使用任何类型的电气连接,电缆,软线或其他电线(包括可移动的和硬的)连接到最终用途应用,则可以被视为AEPS。 有线连接。 以太网电缆将满足这些标准,因此通过以太网电缆连接到最终用途产品的EPS仍将被视为AEPS,并且如果满足其他5条标准,则将遵守适用的节能标准。 AEPS。 通常,所有以太网供电电源适配器都符合所有标准,并且必须达到VI级效率
 

什么是符合IEC 62368-1:2018标准电源?
IEC 62368-12018适用于额定电压不超过600 V的音频,视频,信息和通信技术以及商用和办公领域中的电气和电子设备安全。这是产品安全标准 对能源进行分类,规定针对这些能源的防护措施,并就这些防护措施的应用和要求提供指导。 规定的防护措施旨在减少痛苦,受伤的可能性,并在发生火灾时减少财产损失。 符合IEC 62368-1交流直流转换器或电源是经过测试并证明符合所述标准的电源。

IEC 62368-1电源是否替代了IEC60950-1电源?20201220日,已应用于信息技术设备和音频视频设备的安全标准IEC 60065IEC 60950-1过渡为IEC 62368-1。 在北美,ETLUL 60950-1认证将继续有效,并且可以继续使用直至另行通知。

IEC 62368-1IEC 60950-1电源之间有什么区别?

尽管标准结构和内容总体上有很大不同,但以前符合IEC 60950-1的大多数产品经过很小的修改甚至不用修改都可以符合最新标准IEC 62368-1

IEC60950-1电源是否仍然可用?
GlobTek将继续无限期地制造和供应
IEC 60950-1电源,直至另行通知。

什么是六级能效?

一到六是国际能效标记协议,允许制造商指定产品的效率性能。 此性能基于对在不同负载水平下测试的外部电源或交流转直流适配器的工作能效和空载功耗的测量。 空载功耗是指即使应用程序关闭或断开连接,外部电源也要消耗的电量。

能效是否必须?
些国家和地区,某些产品或某些应用要求达到能效

什么是生态设计指令2009/125 / EC

生态设计指令在欧洲将交流转直流适配器和外部电源的能效和节能最新要求纳入法律。

交流直流适配器如何工作?

交流直流适配器或外置电源由与交流插头相似的外壳中封闭的电源组成,因此,术语为插头类型,插墙式,插入式或插头式电源适配器。 将电源插入电源插座,然后将交流电压通过交流到直流适配器电源转换为直流电压,该直流电压通过输出电缆连接输入到设备中。不同负载水平下测试的电源的工作能效和空载功耗 空载功耗是指即使应用设备关闭或断开连接,外置电源也要消耗的电量。

问询