GTM96180-18VV-T3A Desktop/External ICT / ITE / Medical Power Supply/Class 2/Household Power Supply Datasheet

GTM96180-18VV-T3A Image
Model ImageGTM96180-18VV-T3A, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply,  60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C6 AC Inlet Connector, Class I, Earth Ground  ( aka \
Information
Model NumberGTM96180-18VV-T3A
DescriptionGTM96180-18VV-T3A, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse"), Output Rating: 18 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: IP42; CB 62368; CB 60950; IRAM; Class I; 230V CoC Tier 2; cULus (9V only); EAC; IRAM; UKCA; LPS 62368; NrCAN (9V only); UL 1310; ETL 62368; Conforms to 62368-1; Morocco; S-Mark 62368; Korea (9, 12V Only); cETLus 60601-1 3rd; CE; China RoHS; Level VI; LPS60950; RoHS; Ukraine; VCCI; WEEE; PSE; PSE; FCC; CAN ICES-3; cETLus; ETL; CB 60601-1; RCM; S-Mark 60950; CCC; CE; CB 60335; cETLus UL1310; Fuse 60335; Fuse 60335; GTM96180-18VV-T3A, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse"), Output Rating: 18 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: IP42; CB 62368; CB 60950; IRAM; Class I; 230V CoC Tier 2; cULus (9V only); EAC; IRAM; UKCA; LPS 62368; NrCAN (9V only); UL 1310; ETL 62368; Conforms to 62368-1; Morocco; S-Mark 62368; Korea (9, 12V Only); cETLus 60601-1 3rd; CE; China RoHS; Level VI; LPS60950; RoHS; Ukraine; VCCI; WEEE; PSE; PSE; FCC; CAN ICES-3; cETLus; ETL; CB 60601-1; RCM; S-Mark 60950; CCC; CE; CB 60335; cETLus UL1310; Fuse 60335; Fuse 60335;
Agency Documentshttp://www.globtek.info/certs/GTM96180-TZ/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000OjSVYEA3
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000OjSVYEA3
CE EC-Declaration for Householdhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000OjSVYEA3
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000OjSVYEA3
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000OjSVYEA3
UKCA-Declaration for Householdhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000OjSVYEA3
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000OjSVYEA3
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000OjSVYEA3
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External / 桌面式/外置
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / 开关整流电源
CategoryICT / ITE / Medical Power Supply/Class 2/Household Power Supply / ICT / ITE / Medical Power Supply/Class 2/Household Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)0.6 A
Max Output Power Rating (W)18
Output Voltage Range (V)5-48
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 / Europe Code of Conduct on Energy Efficiency of External Power Supplies - Version 5
Ingress ProtectionIP42
Size (mm)(L)87x(W)47x(H)32mm
EnclosureUser-added image

 
3D File Downloadhttps://www.globtek.com/dl/GTM96180-T3A.igs
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM96180-1607-2.0-T3A*53.216
GTM96180-1807-1.05-T3A*5.95317.85
GTM96180-1811-2.0-T3A*9218
GTM96180-1817.9-5.9-T3A*121.518
GTM96180-1817.9-2.9-T3A*151.218
GTM96180-1830-12.0-T3A*18118
GTM96180-1830-10.0-T3A*200.918
GTM96180-1830-6.0-T3A*240.7518
GTM96180-1830-T3A*300.618
GTM96180-1848-T3A*480.37518
GTM96180-18VV-T3A-XXXXCUSTOMCUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       85% rated load current for 85-264VAC
     100% rated load current for 110-370VDC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
No Load Input Power:<75mW @ 230VAC (EU CoC Tier 2 compliant)
Inrush Current:30A/60A maximum, cold start @ 115VAC/230VAC input, respectively
Efficiency:DoE Level VI compliant, EU CoC Tier 2 compliant

Output

Turn-on Delay:1 second max. @ nominal line and full load
Output Regulation± 5% max. (measured at the output connector)
Line Regulation:± 0.5% typ. (measured at the output connector, full load)
Ripple:1% or 100mV, whichever is greater (measured using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Transient Response:5% max. deviation (with 40-70% load step), 1ms typ. recovery time 
Hold-up Time:8ms typ. @ nominal line and full load
Power On Indicator:Green LED

Protections

Input Protection:MOV transient suppressor, input line fusing
Over-Voltage Protection:110-130% of nominal output voltage
Short-Circuit Protection:Auto-restart
Over-Current Protection:110-160% of rated output current (Current limit range is determined by normal output power rating, not derated power level)

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-20°C to 40°C (full load)
See derating table for output power capability at other temperatures.
Extended low temperature range available as a custom option.
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m
Ingress protection:IP42 standard, IP52 available as a special option
Cooling:Convection
RoHS:Complies with EU 2011/65/EU amended by EU 2015/863 and China SJ/T 11363-2006

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth (Class I models)
Touch Current:Class I models: < 20uA
Class II models: <75uA
Earth Leakage Current:Class I models: <300uA
Class II models: N/A
Isolation Options:Floating output or Class I earthed output (desktop models)
Earth Continuity Test:< 0.1 ohm between AC inlet earth pin and PCB termination point
Means of Protection:2 x MOPP
Compliant Standards:See listing at the end of this document.

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 8KV contact discharge, 20KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
AC Input Mechanical Options:Wall plug-in, changeable blades (Class II only)
Desktop housing, extended housing: C6, C8, C14, or C18 IEC inlet (Class I or Class II)
Markings:Label or laser printed
 

Special Options

  1. Removal of LED (optional)
  2. Custom cord-sets (custom cord and/or connector types). Note: 5VDC USB power supplies with Micro-B or Type-C connectors have a voltage regulation specification of ±8% (4.6V to 5.4V).
  3. Custom markings
  4. Short term output surge capability
  5. Reduced leakage current versions (10uA max) for Type-CF medical applications and/or for AC noise sensitive equipment. (15W or less, 5 to 24V output voltage range.)
  6. Tightened output voltage tolerance
  7. Reduced output voltage ripple
  8. Improved reliability PCB laminate with plated-through-holes for IPC610 Class 2 compliance
  9. Custom housing colors
  10. Quasi constant-current output for SLA (lead-acid) battery charging applications
Derating Curve
User-added image

 
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)430 x 370 x 320
Gross Weight (kg)15.2
Label Width (mm)36.5
Label Height (mm)48.5
Input Configuration
DescriptionIEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse")User-added image

Mates with IEC 60320/C5 Plug

 
 Standard International IEC 320/C5 Cordsets

Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or package with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material. 

Part Number / LinkCountryPlugConnectorLength (mm)Length (ft)
3021066F712(R)N. American (Type B)NEMA 5-15PIEC 320/C518806
1191068F0712(R)N. American (Type B)NEMA 5-15P HospitalIEC 320/C524598
2194262M0712(R)Argentina (Type I)IRAM 2073IEC320/C520506.7
2064262M0712(R)Australian (Type I)AS3112 / 3 PRONGIEC 320/C520006.6
204B4262M0712(R)Brazil (Type N)BRAZILIEC 320/C520006.6
6023592M5712(R)China (Type I)CCC GR2099IEC 320/C525008
23144262M0712(R)Europe (Type E)CEE 7/7IEC 320/C520506.6
2313K3432M0712(R)Korea (Type F)KS C 8305IEC 320/C520006.6
205IN4262M0712(R)India (Type D)India IS 1293 (also known
as IA16A3 or BS546)
IEC320/C520006.6
377C4262M0712(R)Israel (Type H)ISLIEC320/C520506.7
23024262M0712(R)Italy (Type L)CEI 23-16/VIIIEC 320/C520006.6
3003316F0712(R)Japan (Type B)JIS 8303 / 3 PINSIEC 320/C518306
3021066F0712ULPSE(R)Japan / USA (Type B)JIS 8303 / 3 PINS +
NEMA 5-15P
IEC 320/C518306
2054262M0712(R)S. Africa (Type D)South Africa SABS164-1   (6A type plug)IEC320/C520506.7
2084262M0712(R)S.Africa (Type M)South Africa SABS164-1 (16A type plug)IEC 320/C520006.6
23214262M0712(R)Switzerland (Type J)SEV 1011 ( EL 203)IEC 320/C520006.6
3003316F0712(R)Taiwan (Type B)BSMIIEC 320/C520006.6
6104262M0712(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363IEC 320/C520006.6
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
No Logo ApplicableEU 230V CoC Tier 2, 278/2009, Mar 2014
User-added imageBook 60335 up to 36 Volts

No Logo Applicable

IEC 60601-1:2005 (Third Edition) + CORR. 1 (2006) + CORR. 2 (2007) + AM1 (2012) or IEC 60601-1 (2012 reprint) (Ed 3.1)

No Logo Applicable

CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
 User-added imageCCC to GB4943. 1-2011; GB9254-2008; GB17625. 1-2012 with Tropical and Altitude up to 5000 m approval.

No Logo Applicable

IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013
User-added image  CE Mark: tested to comply with EN 55032:2012+AC:2013, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 55024:2010, EN 60601-1-2:2015
User-added image  CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageInformation Technology Equipment Safety Part 1: General Requirements (UL 60950-1 Issued: 2007/03/27, Ed: 2 Rev: 2014/10/14) Information Technology Equipment Safety Part 1: General Requirements (CSA C22.2 No. 60950-1 Issued: 2007/03/27 Ed: 2 (R2012) Amd.
User-added imageConforms to ANSI/UL Std. 60950-1 2nd Edition Cert. to CAN/CSA Std.C22.2 NO.60950-1 2nd Edition
User-added image
Class 2 Power Unit
 
cETLus-Cert 4007497 UL1310 Recognized Component up to 36 volts
User-added image
 
AAMI ES60601-1 Issued: 2012/08/20 Medical Electrical Equipment - Part 1: CAN/CSA-C22.2 No.60601-1:14, Third Edition Issued: 2014/03/01 - Medical Electrical Equipment - Part 1: IEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.- Part 1-11:
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added imageUL 60950-1, 2nd Edition, 2014-10-14 (Information Technology Equipment - Safety - Part 1: General Requirements) CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment - Safety - Part 1: General Requirements) 9V only
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageEnergy verified for GTM96180-1811-2.0-T3A
User-added imageCompliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.
User-added imageFuse 60335 T1.6A 250VAC Up to 36 volts
CAN ICES-3(B)/NMB-3(B)
Compliance of this PSU with Industry Canada, Class B demonstrated with a standard output load. The ICES law stipulates that system-level testing is required to demonstrate compliance with the ICES-3 emission limits with the actual system load.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP42Ingress Protection: ?IP42 to IEC60529:2001 Protection against granular foreign bodies - Protected against direct sprays up to 15o from the vertical Optional
User-added image
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE

 
IRAM certificate to IEC 62368-1:2014
User-added image
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE

 
IRAM certificate DC-E-G71-002.8 to IEC 60950-1:2005 + A1:2009 +A2:2013
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50471561.pdf, to J62368-1(H30) , J55032(H29), J3000(H25) ,[15V?30V]. Please reference the following website for PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50471561, to J62368-1(H30) , J55032(H29), J3000(H25) ,[15V or less]. Please reference the following website for PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added image

 
Korea KET KC Mark GTM96180-1817.9-5.9-T3(A) HU10499-18036A (9,12V)
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source 60950
LPSLimited Power Source 62368
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added imageNatural Resources Canada (NRCan): CSA Standard C381.1-08, QSP NRCAN EEV1191; http://shop.csa.ca/en/canada/energy-efficiency/cancsa-c3811-08/invt/27024802008 (9V output only)
User-added image
 
RCM certificate SAA-161679-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageS-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
User-added image
 
S-Mark Certificate EN 62368-1:2014 + A11 (http://www.intertek.com/marks/s/)
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageUL1310 Warning Label Up To 36 Volts with plugs
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request

什么是IEC 60601-1医疗级额定电源交流适配器?

IEC 60601-1-2医疗级额定电源交流适配器将来自墙壁的输入线路电压转换为较低的电压,通常为直流,该电压用于操作和最终使用医疗设备。 IEC 60601-1-2医疗级电源交流适配器通常装在塑料外壳中,并提供2脚和3脚输入选项。另外开放式电源医疗设备内部.这些交流转直流转换器是根据国际医学标准设计的,并确保它们符合某些方面的要求,不同于通用信息和通信技术设备的电源。
 

为什么医疗级IEC 60601-1电源通过了IEC 60601-13版认证,而最新标准IEC 60601-14版?

IEC 60601-1在安全和EMI / EMC规范中有区分IEC 60601-1安全部分的最新版本是第三版,而EMI / EMC的最新版本是60601-1-2,第四版。

 

第四版60601-1-2什么时候生效?

第四版60601-1-220181231日起生效。

 

IEC 60950-1IEC 60601-1医疗级额定电源有什么区别?

IEC 60950-1IEC 60601-1-2电源都是起到交流电转直流电的作用,可以是内或外根据应用终端的不同规格要求而设计。 尽管例如输入和输出电压以及结构等类似,但也存在许多差异。 例如一些重要区别在于,医用IEC 60601医用级交流转直流适配器能够承受较高电压,并且必须具有较低的漏电流。 根据终端应用的不同,还有许多其他差异和考虑因素。

什么是MOOP (MEANS OF OPERATOR PROTECTION )对操作者提供足够防护 和MOPP (MEANS OF PATIENT PROTECTION) 对病患提供足够防护
医疗设备必须包含一种或多种保护手段(MOP),以使患者和操作员免受电击危险。 保护手段(MOP)可以是安全绝缘,保护性接地,规定的爬电距离或气隙或其他保护性阻抗。 这些可以各种组合使用。 IEC 60601-13版区分了对患者的风险和对操作人员的风险。 因此,MOP可以分类为患者保护方式(MOPP)或操作员保护方式(MOOP)。 MOOPMOPP之间的主要区别是允许的爬电距离。 使用基本绝缘可以满足这两个要求。 为了获得2倍的MOPP认证,隔离测试在4000 Vac时特别要求,8mm的爬电距离是MOPP所要求的两倍。

什么是主体触体绝缘型和心脏触体绝缘型符合IEC 60601-1-2医疗级额定电源交流适配器,有什么区别?

医用级电源和交流转直流适配器分为三种应用部件类型:主体类型(B),主体触体绝缘型(BF)和心脏触体绝缘型(CF)。这些应用的零件需要特定的属性,例如隔离电压,爬电距离和漏电流。绝缘是指未接地的II类电源,该电源未关联到另一个输出且已完全隔离。 B型是指在患者附近工作的设备,如IEC 60601-1中所述,围绕患者的椅子或床六英尺,并且不通过电子方式接触患者并且接地。这些设备包括手术室照明设备,医院推车和床,药物和补给品的自动分配器以及X射线机之类的诊断设备。 BF型设备向患者或从患者发送电能信号,例如电外科设备,内窥镜和生命体征电子监护仪(例如温度计)。 CF型设备与BF类似,不同之处在于它们为连接到心脏的设备(例如除纤颤器,外部起搏器或心内心电图电极)供电,并且CF型需要比BF型更高的电击防护等级。

POE电源是否需要VI级效率?
根据美国能源部的规定,如果EPS使用任何类型的电气连接,电缆,软线或其他电线(包括可移动的和硬的)连接到最终用途应用,则可以被视为AEPS。 有线连接。 以太网电缆将满足这些标准,因此通过以太网电缆连接到最终用途产品的EPS仍将被视为AEPS,并且如果满足其他5条标准,则将遵守适用的节能标准。 AEPS。 通常,所有以太网供电电源适配器都符合所有标准,并且必须达到VI级效率
 

什么是符合IEC 62368-1:2018标准电源?
IEC 62368-12018适用于额定电压不超过600 V的音频,视频,信息和通信技术以及商用和办公领域中的电气和电子设备安全。这是产品安全标准 对能源进行分类,规定针对这些能源的防护措施,并就这些防护措施的应用和要求提供指导。 规定的防护措施旨在减少痛苦,受伤的可能性,并在发生火灾时减少财产损失。 符合IEC 62368-1交流直流转换器或电源是经过测试并证明符合所述标准的电源。

IEC 62368-1电源是否替代了IEC60950-1电源?20201220日,已应用于信息技术设备和音频视频设备的安全标准IEC 60065IEC 60950-1过渡为IEC 62368-1。 在北美,ETLUL 60950-1认证将继续有效,并且可以继续使用直至另行通知。

IEC 62368-1IEC 60950-1电源之间有什么区别?

尽管标准结构和内容总体上有很大不同,但以前符合IEC 60950-1的大多数产品经过很小的修改甚至不用修改都可以符合最新标准IEC 62368-1

IEC60950-1电源是否仍然可用?
GlobTek将继续无限期地制造和供应
IEC 60950-1电源,直至另行通知。

什么是六级能效?

一到六是国际能效标记协议,允许制造商指定产品的效率性能。 此性能基于对在不同负载水平下测试的外部电源或交流转直流适配器的工作能效和空载功耗的测量。 空载功耗是指即使应用程序关闭或断开连接,外部电源也要消耗的电量。

能效是否必须?
些国家和地区,某些产品或某些应用要求达到能效

什么是生态设计指令2009/125 / EC

生态设计指令在欧洲将交流转直流适配器和外部电源的能效和节能最新要求纳入法律。

什么是欧洲CoC Tier 2法规?

欧洲CoC Tier 2法规是欧盟委员会JRC(联合研究中心)可再生能源部门发布的一套针对外部电源和AC适配器的效率目标。 这些目标是非强制性的,没有任何法律强制规定。

交流直流适配器如何工作?

交流直流适配器或外置电源由与交流插头相似的外壳中封闭的电源组成,因此,术语为插头类型,插墙式,插入式或插头式电源适配器。 将电源插入电源插座,然后将交流电压通过交流到直流适配器电源转换为直流电压,该直流电压通过输出电缆连接输入到设备中。不同负载水平下测试的电源的工作能效和空载功耗 空载功耗是指即使应用设备关闭或断开连接,外置电源也要消耗的电量。

问询
Call
Email
💬
Text
💁
Chat
?
询价
我们可以帮助您?
我们可以帮助您?